[Oct 10, 2024] Powerful D-VXR-DY-23 PDF Dumps for D-VXR-DY-23 Questions [Q103-Q128]

Share

[Oct 10, 2024] Powerful D-VXR-DY-23 PDF Dumps for D-VXR-DY-23 Questions

Authentic D-VXR-DY-23 Dumps - Free PDF Questions to Pass

NEW QUESTION # 103
What is the base URL for the VxRail API call?

  • A. https://<VxM_IP>/API/vxm/v1/
  • B. https://<VxM_IP>/rest/vxm/v1/
  • C. http://<VxM_IP>/vxm/v1/
  • D. https://<VCenter_IP>/rest/vxm/v1/

Answer: B


NEW QUESTION # 104
What is a valid 2-node VxRail cluster in a direct-connect configuration?

  • A. E Series with 2x 1 GbE and 2x 10 GbE and external vCenter
  • B. P Series with 2x 1 GbE and 2x 10 GbE and internal vCenter
  • C. D Series with 4x 25 GbE and internal vCenter
  • D. G Series with 4x 10 GbE and external vCenter

Answer: A


NEW QUESTION # 105
The Market Place on a VxRail Manager is empty on a newly deployed system. Testing shows that the Internet is reachable through proxy in the management network.
Which action should be taken to correct this situation?

  • A. VxRail Manager has no proxy support.
  • B. Reset the appliance and redeploy with proxy information filled in the deployment process.
  • C. Upgrade to latest version and add proxy configuration manually.
  • D. Manually add the proxy information in the VxRail Manager configuration

Answer: D


NEW QUESTION # 106
You are performing a troubleshooting steps on a 4 node VxRail cluster. The cluster uses Erasure Coding for all VMs. When you attempt to put a node into maintenance modeusing the recommended vSAN data migration policy, the operation fails.
What could be done to successfully put the node into maintenance mode?

  • A. Storage vMotion the VMs off the node
  • B. Use the 'No Data Migration' option
  • C. Use the 'Full Data Migration' option
  • D. Cold migrate the VMs off the node

Answer: C


NEW QUESTION # 107
Which series of VxRail nodes is designed to support a large MongoDB environment that is being used for data analytics?

  • A. P Series
  • B. V Series
  • C. G Series
  • D. S Series

Answer: A


NEW QUESTION # 108
What is the correct sequence of steps to perform a RASR Factory Reset using an SD card?

Answer:

Explanation:


NEW QUESTION # 109
A VxRail cluster 4.7.xxx environment is managed by the internal vCenter Server. An implementation engineer plans to deploy a new VxRail cluster using the existing vCenter Server instance, then use the customer-supplied VDS to manage both VxRail clusters.
What must be done?

  • A. Upgrade the internal vCenter Server to version 7.0
  • B. Migrate the internal vCenter Server to an external vCenter Server, then merge the PSC
  • C. Upgrade the VxRail version from 4.7.xxx to 7.0.000
  • D. Migrate the internal vCenter Server to an external vCenter Server, then upgrade the VxRail 4.7.xxx to 7.0.100

Answer: D


NEW QUESTION # 110
A VxRail deployment has just been completed but the vSAN performance statistics are not available for the cluster or virtual machines.
What is the reason for this situation?

  • A. vSAN performance hot-fix has not been applied
  • B. Monitoring policy has not been created
  • C. Data has not been populated
  • D. Performance service has not been manually enabled

Answer: B


NEW QUESTION # 111
What is the correct CLI command to collect only the vCenter logs on VxRail Manager?

  • A. generateLogBundle.py -c
  • B. generateFullBundle.py -v
  • C. vc-support-bundle.sh -c
  • D. vc-support.sh -v

Answer: A


NEW QUESTION # 112
You are attempting to reset a single G Series node running 4.0.x code to the factory default. You discover that the configbundle.tgz file is corrupt.
What is the recommended method to recover the node?

  • A. Node Replacement
  • B. Reset Script
  • C. Mobile Build Server
  • D. Rapid Appliance Self Recovery

Answer: C


NEW QUESTION # 113
Which VxRail configurations can be reviewed using the As-Built Configuration Report at the time the report is generated?

  • A. Node PSNT numbers, license activation dates, and Private Management Network VLAN ID
  • B. Node models, license keys, vSAN VLAN ID, and vMotion VLAN ID
  • C. vMotion interface IP addresses, vCenter users and passwords, and opened firewall ports
  • D. Node names, vSAN interface IP addresses, and VxRail Manager users and passwords

Answer: B


NEW QUESTION # 114
What is a consideration when adding nodes to a VxRail G Series chassis?

  • A. Hybrid and All-Flash nodes are permitted, if in different chassis
  • B. All nodes in a G Series chassis must be identical
  • C. G Series can only scale up to 8 nodes
  • D. In a full G Series chassis, all nodes must have 10GbE ports

Answer: B


NEW QUESTION # 115
In addition to the VxRail YouTube video, links to what resources should the SE send to the customer, according to the VxRail PEQ Engagement Details worksheet?

  • A. VxRail vCenter Server Planning Guide Network Validation Tool
  • B. VxRail vCenter Server Planning Guide VxRail Network Guide
  • C. VxRail QuickStart Guide Network Validation Tool
  • D. VxRail QuickStart Guide VxRail Network Guide

Answer: C


NEW QUESTION # 116
A new enterprise customer will be deploying VxRail, utilizing an existing vCenter.
Which server will be used to add and validate the host and domain names?

  • A. Customer external vCenter with host file
  • B. Internal DNS server on VxRail Manager
  • C. Customer external DNS server
  • D. Internal DNS server deployed on node1

Answer: C


NEW QUESTION # 117
From what location should NVT for VxRail be run?

  • A. Workstation on the same network as VxRail Manager
  • B. Laptop connected to the first VxRail ESXi node
  • C. VxRail network Top of Rack switch
  • D. Jump server on a different network

Answer: A


NEW QUESTION # 118
Which step must occur prior to deploying a 2 node VxRail Cluster?

  • A. Cluster object created in vCenter
  • B. Witness deployed and running
  • C. All ports connected to ToR switch
  • D. Witness Traffic Separation configured

Answer: B


NEW QUESTION # 119
Which port configuration is invalid on the integrated NIC of a VxRail node?

  • A. 2 x 10 GbE SFP+
  • B. 2 x 1 GbE RJ45
  • C. 2 x 25 GbE SFP28
  • D. 2 x 10 GbE RJ45

Answer: B


NEW QUESTION # 120
Beginning with VxRail version 4.7, which product license option has changed?

  • A. vSAN
  • B. Mware Log Insight
  • C. vSphere
  • D. vCenter

Answer: A


NEW QUESTION # 121
A VxRail running version 4.7.100 has been deployed in a SmartFabric configuration. The customer needs to set up management of their networking for the Cluster.
What steps are required to complete this task?

  • A. Download and install OME plug-in
  • B. Download the OMNI plug-in, enable vCenter, and run the Python script
  • C. Download, install the OME plug-in, and run the Python script
  • D. Download and install the OMNI plug-in

Answer: D


NEW QUESTION # 122
What must be enabled on ToR switch ports connected to VxRail nodes to support multiple VLANs?

  • A. Access Mode
  • B. Rapid Spanning Tree
  • C. Link Aggregation
  • D. Trunk Mode

Answer: D


NEW QUESTION # 123
Based on the exhibit, what is the correct IP address to use when resetting a G Series node with the reset script?

  • A. 169.254.234.124
  • B. 192.168.80.35
  • C. 192.168.20.35
  • D. 192.168.30.35

Answer: D


NEW QUESTION # 124
Which VxRail Pre-Installation Site Checklist worksheet is auto-populated?

  • A. Begin Here
  • B. Switch Config Actuals
  • C. Network Basics
  • D. VxRail Network Configuration

Answer: C


NEW QUESTION # 125
What is the difference between Compression only and Deduplication and compression on a VxRail vSAN cluster?

  • A. Compression only: A failed capacity disk causes the disk group to go offline Deduplication and compression: A failed capacity disk does not impact the entire disk group
  • B. Compression only: Does not require a rolling reformat of the disks when enabled Deduplication and compression: Requires a rolling reformat of the disks when enabled
  • C. Compression only: A failed capacity disk does not impact the entire disk group Deduplication and compression: A failed capacity disk causes the disk group to go offline
  • D. Compression only: Added capacity disk requires a disk group rebuild
    Deduplication and compression: Added capacity disk does not require a disk group rebuild

Answer: C


NEW QUESTION # 126
View the Exhibit.

Based on the exhibit, which interfaces should be used to reset the node through the Mobile Build Server?

  • A. 1 and 2
  • B. 1, 2 and 3
  • C. 2 and 3
  • D. 1 and 3

Answer: D


NEW QUESTION # 127
An implementation engineer is expanding an existing VxRail S Series cluster with an additional node. The version of the node is not at the current cluster level but is compatible.
What procedure would result in the quickest node addition?

  • A. RASR Factory Image Upgrade
  • B. Compute node expansion
  • C. Factory Reset
  • D. VxRail Node Imaging Management

Answer: B


NEW QUESTION # 128
......

Guaranteed Accomplishment with Newest Oct-2024 FREE: https://www.pass4surequiz.com/D-VXR-DY-23-exam-quiz.html

Use Valid New Free D-VXR-DY-23 Exam Dumps & Answers: https://drive.google.com/open?id=1sFSEBLL3eDzbB_SxnMjlqQn81203ixnX